Bronkhorst

EL-FLOW Select F-231M

High-Pressure Mass Flow Controller for Gases

  • Operating pressure / delta-P up to 350 bar
  • Stable control, even at variable pressure conditions
  • High accuracy
  • Virtually pressure and temperature independent
  • Compact design
お見積り依頼 Downloads Datasheet
EL-FLOW Select F-231M

Gas Mass Flow Controllers for high pressure / high delta-P

Bronkhorst® model F-231M Mass Flow Controllers (MFCs) are suited for accurate measurement and control of flow ranges between 0,01…0,5 ln/min and 0,2…10 ln/min at operating pressures up to 350 bar as well as max. 350 bar pressure difference (ΔP). The MFC consists of a thermal mass flow sensor, a precise control valve and a microprocessor based pc-board with signal and fieldbus conversion. As a function of a setpoint value, the flow controller swiftly adjusts the desired flow rate.

EL-FLOW® Select series are equipped with a digital pc-board, offering high accuracy, excellent temperature stability and fast response. The main digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output the instruments also offer analog I/O. As an option, an on-board interface can be mounted to provide CANopen®, DeviceNet™, EtherCAT®, PROFIBUS DP, PROFINET, Modbus RTU, ASCII or TCP/IP, EtherNet/IP, POWERLINK or FLOW-BUS protocols.


Technical specifications

Measurement / control system
Flow range (intermediate ranges available)min. 0,01…0,5 ln/min
max. 0,2…10 ln/min
(based on N2)
Accuracy (incl. linearity) (based on actual calibration)± 0,5 % RD plus ±0,1% FS
Repeatability< 0,2 % RD
Turndown ratio1:50
Multi fluid capabilityStorage of max. 8 calibration curves
Settling time (in control, typical)2 … 4 sec.
Control stability< ± 0,1 % FS
Operating temperature-10 … +70 °C
Temperature sensitivityzero: < 0,05% FS/°C; span: < 0,05% Rd/°C
Pressure sensitivity< 0,1% Rd/bar typical N2; 0,01% Rd/bar typical H2
Leak integrity, outboardtested < 2 x 10-9 mbar l/s He
Attitude sensitivitymax. error at 90° off horizontal 0,2% at 1 bar, typical N2
Warm-up time30 min. for optimum accuracy
2 min. for accuracy ± 2% FS
Mechanical parts
Material (wetted parts)Stainless steel 316L or comparable
Pressure rating (PN)350 bar abs
Min. ΔP6 bar dif.
Max. ΔPup to 350 bar dif.
Process connectionscompression type or face seal (VCR/VCO) couplings
Sealsstandard: FKM/Viton®;
options: EPDM, FFKM/Kalrez®
Weight3,4 kg
Ingress protectionIP40
Electrical properties
Power supply+15 … 24 Vdc
Max. power consumption
Supply
15 V
24 V
at voltage I/O
290 mA
200 mA
at current I/O
320 mA
215 mA
extra for fieldbus
<75 mA
<50 mA
Analog output0…5 (10) Vdc or 0 (4)…20 mA (sourcing output)
Digital communicationstandard: RS232;
options: PROFIBUS DP, CANopen®, DeviceNet™, PROFINET, EtherCAT®, Modbus RTU, ASCII or TCP/IP, EtherNet/IP, POWERLINK, FLOW-BUS
Electrical connection
Analog/RS2329-pin D-connector (male);
PROFIBUS DPbus: 9-pin D-connector (female);
power: 9-pin D-connector (male);
CANopen® / DeviceNet™5-pin M12-connector (male);
FLOW-BUS/Modbus-RTU/ASCIIRJ45 modular jack
Modbus TCP / EtherNet/IP / POWERLINK2 x RJ45 modular jack (in/out);
EtherCAT®/ PROFINET2 x RJ45 modular jack (in/out)
Control valve options
External actuator options to be connected to the controller
Certification for hazardous areas
Approvals / certificates

Technical specifications subject to change without notice.

For dimensional drawings and hook-up diagrams please visit the product page on our website

Downloads

Brochures
EL-FLOW Select brochure
Manuals
Quick installation guide EL-FLOW Select
Manual EL-FLOW Select
Hook-up diagrams
Analog IO - RS232
DeviceNet
EtherCAT
FLOW-BUS
Modbus RTU/ASCII
PROFIBUS DP
PROFINET
CANopen
EtherNet/IP
Modbus-TCP
POWERLINK
Optional Bus and IO Configurations
Dimensional drawings
Dimensional Drawing F-230M_F-232M_F-232M
Dimensions Digital Cases
Dimensions Adapters


ブロンコスト・ジャパン株式会社
〒135-0016
東京都江東区東陽5-27-5

Tel.  03-3645-1371

sales◎bronkhorst.jp   ◎を@に置き換えて下さい

     
Copyright © 2024 Bronkhorst. All rights reserved.     サイトマップ     免責事項     プライバシーポリシー