Efficiency and yield in a process require a stable gas flow. This gas flow can be measured and controlled by a thermal mass flow controller. As a Product Manager at Bronkhorst High-Tech, I experienced that various external factors can have influence on the measurement accuracy and control stability of mass flow controllers (MFCs).
Some examples of external factors are:

  • Temperature fluctuations
  • Line-pressure fluctuations
These fluctuations can occur due to reduced pressure in a gas cylinder or due to cross talk between multiple flow controllers. How does Bronkhorst solve these problems, and what solutions do we offer?

Cross talk with mass flow controllers

What is cross talk? Cross talk typically arises when multiple mass flow controllers are positioned in close proximity in the same pipe, or installed upon the same rail or frame. The line-pressure from a gas regulator is affected by the flow demand of the flow controllers. When the flow instrument is changing its setpoint, it will affect the line-pressure. Due to this pressure change, the flow measuring section in a conventional flow controller is affected, indicating an incorrect flow measurement that does not represent the actual flow through the MFC.

The smaller the nominal flow of the flow controller, the bigger the effect will be to a setpoint change of a larger, parallel installed MFC.


Static and dynamic pressure compensation

Static pressure compensation is the compensation for slow pressure changes, for example the slowly reduced pressure from a gas cylinder. By integrating a pressure transmitter to the mass flow controller, together with an on-board conversion algorithm, real-time calculation of the actual fluid properties can be performed. For semi-caloric measurement the density, viscosity, thermal conductivity and heat capacity are used in the calculation. Under influence of pressure and temperature, these properties change.  Thus, actual temperature and pressure are measured and processed, resulting in accurate flow measurement and control stability.

Dynamic compensation, insensitive to pressure changes
Dynamic compensation, insensitive to pressure changes

Dynamic pressure compensation is the compensation for rapid pressure changes. This can occur when a higher-flow mass flow controller on the same supply line changes setpoint, an undesired effect which is also known as ‘cross talk’. The moment that these rapid pressure changes are identified by the pressure sensor, the valve control will be adjusted accordingly so that the flow remains stable.

Stable flow control with on-board conversion

The on-board conversion algorithm makes it possible to convert the stored calibration fluid into one of the 25 on-board gases (multi-fluid multi-range functionality).
The actual measured temperature and pressure is used in the on-board conversion model to compensate for changes in the process conditions.  This leads to a more reliable and accurate conversion and control stability.

More simple setup with mass flow meter containing ‘pressure insensitive’
More simple setup with mass flow meter containing ‘pressure insensitive’
new EL-FLOW Prestige PI (Pressure Insensitive) now available
New EL-FLOW Prestige PI (Pressure Insensitive) now available

Benefits for the user

  1. Firstly, due to the improved and accurate flow measurement and control, optimized and more constant process conditions are possible, resulting in an improvement of your process yield.
  2. Secondly, ease of installation since there is no need for exactly providing/meeting the process conditions the instrument was ordered for.
  3. Thirdly, because the supplied line pressure becomes less important for the accuracy and control stability of the instrument, less accurate components or even reduction of components in the supply line are needed. This allows saving costs on, for example, a pressure regulator.

Pressure Insensitive Gas Mass Flow Controllers for low flow rates

To learn more about the EL-FLOW Prestige Pressure Insensitive, please visit our product page.
 

EL-FLOW Prestige Pressure Insensitive

Bronkhorst High-Tech B.V.

Nijverheidsstraat 1A
NL-7261 AK Ruurlo (NL)
Tel. +31 573 45 88 00
info@bronkhorst.com

Copyright © 2018 Bronkhorst. All rights reserved.     Sitemap     Disclaimer     Privacy note