Bronkhorst

MAG-VIEW MVM-002-PN

Low-Flow Magnetic Inductive Flow meters for water-like liquids

  • Compact, weatherproof (IP65) design
  • No moving parts (no mechanical wear)
  • Interference free operation
  • Independence to inlet/outlet pipework
  • Fast response
  • Free pipe cross section: low ΔP, insensitive to contamination
  • Pulse output
MASSFLOW-ONLINE product
  Obtenir une offre de prix Téléchargements Acheter maintenant Support
MAG-VIEWMVM-002-PN

Electromagnetic flow meters for low flow rates of water and aqueous solutions

MAG-VIEW instruments are electromagnetic inductive flow meters for electrically conductive liquids with a minimum conductivity of 50 μS/cm. The compact, weatherproof (IP65) flow meters do not contain any moving parts, cause virtually no pressure loss and can be mounted in any position, requiring no straight inlet or outlet runs.

MAG-VIEW flow meter model MVM-002-PN has a nominal diameter of DN2 for flow rates of 0,05...2 l/min, suited for operating pressures up to 16 bar(g). The pulse output of the instrument is proportional to the flow.


Spécifications techniques

Système de mesure / régulation
Débits0,05 … 2 l/min
Précision du débit volumique±1% RD at 0...50% of measuring range
±2% RD at 50...100% of measuring range
(incl. factory calibration certificate; test conditions: water 23°C)
Rangeabilité1:40
Reproductibilité1 % FS
Sortie du signal à partir de~ 0,05 l/min
MédiaWater and other conductive liquids
(minimum conductivity of 50 μS/cm)
Temps de réponse (capteur)< 500 msec
Température moyenne-20 … 90 °C
MontageAny position, attitude insensitive
Flow indicationgreen LED, flow proportional flashing
Parties mécaniques
Matériau (pièces en contact avec le fluide)Electrodes: Stainless Steel 1.4571
Process connections: Stainless Steel 1.4571
Measuring pipe: PEEK-GF30
Gasket: EPDM
BoîtierAluminium pressure diecasted
DiamètreDN2
Raccords de process1/4" BSP male thread
Protection IPIP65
Pression nominalePN16
Propriétés électriques
Alimentation électrique24 Vdc ±10 %
Consommation d'électrique max.150 mA
Sortie fréquencePulse rate / K-factor : 10000 pulses/l
Resolution : 0,1 ml/pulse
Signal shape : Square wave signal - duty cycle 50:50
Push-Pull - NPN open collector [o.c.] - PNP o.c.
Signal current : max. 100 mA, current limited
Mesures de la protection électriqueShort-circuit proof, protected against polarity reversal
Raccordement électrique5-pin-plug M12x1
Raccordement électrique
Options vanne de régulation
Options actionneur externe à connecter au régulateur
Spécifications Ex-proof
Certifications / certificats

Les spécifications techniques peuvent être modifiées sans préavis.

Pour les schémas d'encombrements et les schémas de câblage, visitez le/la page produits sur notre Site internet

Downloads

Brochures
MAG-VIEW Brochure


BRONKHORST (SCHWEIZ) AG

Gewerbestrasse 7
4147 Aesch BL (CH)
Tel. +41 61 715 90 70
info@bronkhorst.ch

        Responsabilite Sociale
Copyright © 2022 Bronkhorst. All rights reserved.     Sitemap     Disclaimer     Privacy note