Bronkhorst

EX-FLOW F-231MX

High-Pressure Mass Flow Controller for Gases, Ex-proof style

  • ATEX approval Cat.2, Zone 1
  • Also IECEx and TIIS certified
  • High accuracy, excellent repeatability
  • Virtually pressure and temperature independent
  • Operating pressure / delta-P up to 400 bar
Get a quote Request a demo Support

Intrinsically Safe Gas Mass Flow Controllers for High Pressure / High Delta-P

Bronkhorst® EX-FLOW Mass Flow Controllers (MFCs) are suited for precise gas flow control in ATEX Zone 1 hazardous areas. The flow meter part and the control valve of the MFC should be connected (via separate cables) to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone) which contains a controller board to complete the control loop. See Bronkhorst® E-8000 Series.

EX-FLOW model F-231MX covers flow ranges from 10...500 mln/min up to 0,2...10 ln/min (N2-equivalent) at operating pressures up to 400 bar and max. 400 bar pressure difference (ΔP).

The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
The intrinsically safe valve coils are explosion proof certified and available in two options (ATEX certification only):
Coil XB: protection II 1 G Ex ia IIC T6 / protection II 1 D Ex ta IIIC T80°C
Coil XC: protection II 2 G Ex eb IIC T4 / protection II 2 D Ex tb IIIC T130°C


Technical specifications

Measurement / Control system
Flow range, based on N2
(intermediate ranges available)
min. 10...500 mln/min
max. 0,2...10 ln/min

Accuracy (incl. linearity)
(based on actual calibration)

±1% FS
Turndown 1:50 (2...100%)
Repeatability < 0,2% Rd

Time constant

5 seconds
Control stability ≤ ±0,1% FS typical
Operating temperature -10…+65°C
Temperature sensitivity zero: < 0,05% FS/°C; span: < 0,05% Rd/°C
Leak integrity, outboard tested < 2 x 10-9 mbar l/s He
Attitude sensitivity max. error at 90° off horizontal 0,2% FS at 1 bar, typical N2
Warm-up time 30 min. for optimum accuracy
2 min for accuracy ± 2% FS
Mechanical parts
Material (wetted parts) stainless steel 316L or comparable
Pressure rating 400 bar abs
Min. ΔP 6 bar dif.
Max. ΔP up to 400 bar dif.
Process connections compression type or face seal couplings
Seals standard: Viton®; options: EPDM, Kalrez® (FFKM)
Ingress protection (housing) IP65
Electrical properties
Signal circuit type of explosion protection: intrinsic safety Ex ib IIC, only for connection to a certified intrinsically safe circuit with the following maximum values:
  Ui = 28 V, Ii = 98 mA, Pi = 686 mW
  The effective internal capacitance between:
  Terminals 1 and 3: Ci = 1 nF;
  Effective internal inductance: Li = 0,3 mH
Output signal 15…20 mA (linear)

I/O signals via PS/Readout
(located in safe area)

analog: 0...5 Vdc, 0...10 Vdc, 0...20 mA, 4...20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW-BUS
XB-coil Coil voltage max. 28 V/110 mA;
295 Ohm at 20°C
XC-coil Coil voltage max. 24 V;
65 Ohm at 20°C, Pmax = 9 W at 20°C
Electrical connection
Ex-proof measuring head Terminal connection, cable gland M16x1,5
Control valve coil cable gland M20x1,5

Technical specifications and dimensions subject to change without notice.
For dimensional drawings and hook-up diagrams please visit the productpage on our website

Downloads

Brochures
EX-FLOW brochure

Manuals
Manual EX-FLOW meters and controllers - ATEX
Manual EX-FLOW meters and controllers - IECEx
Manual EX-FLOW meters and controllers - TIIS

Dimensional drawing
Dimensional drawing F-230MX-F-231MX-F-232MX


Bronkhorst High-Tech B.V.

Nijverheidsstraat 1A
NL-7261 AK Ruurlo (NL)
Tel. +31 573 45 88 00
[email protected]

Copyright © 2018 Bronkhorst. All rights reserved.     Sitemap     Disclaimer     Privacy note