Bronkhorst

MAG-VIEW MVM-200-QA

Low-Flow Magnetic Inductive Flow meters for water-like liquids

  • Compact, weatherproof (IP65) design
  • No moving parts (no mechanical wear)
  • Independence to inlet/outlet pipework
  • Fast response
  • Free pipe cross section: low ΔP, insensitive to contamination
  • Cost-optimized (plastic) model
MASSFLOW-ONLINE product
  Angebot anfragen Downloads jetzt kaufen Datasheet
MAG-VIEWMVM-200-QA

Electromagnetic flow meters for low flow rates of water and aqueous solutions

MAG-VIEW instruments are electromagnetic inductive flow meters for electrically conductive liquids with a minimum conductivity of 20 μS/cm. The compact, weatherproof (IP65) flow meters do not contain any moving parts, cause virtually no pressure loss and can be mounted in any position, requiring no straight inlet or outlet runs.

MAG-VIEW flow meter model MVM-200-QA is a cost-efficient instrument with a DN15 PVDF measuring tube for flow rates of 5…200 l/min, suited for operating pressures up to 10 bar(g). The analog and pulse output signals of the instrument are proportional to the flow.


Technische Spezifikationen

Mess- / Regelsystem
Durchflussmengen5 … 200 l/min
(max. flow 240 l/min)
Genauigkeit des Volumenstroms± 1 % RD
(inkl. Werkskalibrierzertifikat; Testbedingungen: Wasser 23°C)
Wiederholgenauigkeit1 % FS
Turndown-Bereich1:20 (5…100%)
Signalausgang ab~ 4 l/min
MedienWater and other conductive liquids
(minimum conductivity of 20 μS/cm)
Ansprechzeit (Sensor)< 100 msec
BetriebstemperaturMedium -10...60°C,
Ambient 5...60°C, not freezing
EinbauAny position, attitude insensitive
Durchflussanzeigeblinking green LED
Mechanische Teile
Werkstoff (medienberührte Teile)Electrodes and grounding rings: Stainless Steel 316L
Measuring pipe: PVDF
Process connections: PVDF
GehäuseABS
DurchmesserDN20
Prozessanschlüsse1" BSP male thread
DichtungenEPDM
Schutzart (Gehäuse)IP65
Nominal-Druckmax. 10 bar at 20°C, 8 bar at 40°C, 6 bar at 60°C
Elektrische Eigenschaften
Spannungsversorgung12 … 24 Vdc ±10 %
Stromaufnahme max.3,6 W
Analoges Ausgangssignal4 … 20 mA
Frequenz-AusgangPulse rate / K-factor : 200 pulses/l
Resolution : 5,0 ml/pulse
Signal shape : Push-Pull
Signal current : max. 25 mA
Elektrische SchutzmaßnahmenShort-circuit proof,
protected against polarity reversal
Elektrische Anschlüsse4-pin-plug M12x1
Elektrische Anschlüsse
Optionen Regelventil
Externe Antriebsmöglichkeiten zum Anschluss an das Instrument
Zertifizierung für explosionsgefährdete Bereiche
Zulassungen / Zertifikate

Technische Daten können ohne Vorankündigung geändert werden.

Für Maßzeichnungen und Anschlusspläne besuchen Sie die Produktseite auf unserer webseite

Downloads

Brochures
MAG-VIEW Brochure


Bronkhorst Deutschland nord gmbh

Südfeld 1b
59174 Kamen (GER)
Tel. +49 230792512-0
[email protected]

         Verantwortung und Nachhaltigkeit
Copyright © 2024 Bronkhorst. Alle Rechte vorbehalten.     Sitemap     Haftungsausschluss     Datenschutz     Impressum