Bronkhorst

LIQUI-FLOW™ 'Industrial Style' L13I

Digital Thermal Liquid Mass Flow Meter, Industrial Style

  • Fast and accurate measuring signal
  • Insensitive to mounting position
  • Suitable for liquids with low boiling points
  • Analog, RS232 or fieldbus communication
  • Rugged, IP65 enclosure

  Get a quote Request a demo Support
LIQUI-FLOW™ 'Industrial Style'L13I

Liquid Mass Flow Meters for low flow rates, industrial style

Bronkhorst® model L13I Liquid Flow Meters (LFMs) are suited for precise measurement of flow ranges between 0,25…5 g/h and 5...100 g/h at operating pressures up to 100 bar. The LFM consists of a thermal mass flow sensor and a microprocessor based pc-board with signal and fieldbus conversion and a PID controller for optional mass flow control by means of a separately mounted control valve. The "Industrial Style" LIQUI-FLOW™ model is of rugged design (IP65) for use in industrial environments or even Zone 2 hazardous areas, with optional ATEX Cat. 3 approval.

LIQUI-FLOW™ series are equipped with a digital pc-board, offering high accuracy, excellent temperature stability and fast response. The main digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output the instruments also offer analog I/O. As an option, an on-board interface can be mounted to provide DeviceNet™, PROFIBUS DP, Modbus or FLOW-BUS protocols.


Technical specifications

Measurement system
Flow range, based on H2O
(intermediate ranges available)
min. 0,25…5 g/h
max. 5...100 g/h
Accuracy (incl. linearity)
(based on actual calibration)
±1% FS
Turndown FS <50 g/h : 1:20 (5...100%);
FS >50 g/h : 1:50 (2...100%)
Repeatability < 0,2% FS (typical H2O)
Operating temperature 5…50°C
Temperature sensitivity ±0,1% FS/°C
Attitude sensitivity negligible
Warm-up time 30 min. for optimum accuracy;
2 min for accuracy ± 2% FS
Mechanical parts
Material (wetted parts) stainless steel 316L/320;
others on request
Pressure rating 100 bar abs
Process connections compression type or face seal couplings
Seals Kalrez®-6375;
others on request
Ingress protection (housing) IP65
Electrical properties
Power supply +15…24 Vdc +/-10%
Max. power consumption
(meter only)
Supply
15 V
24 V
at voltage I/O
100 mA
65 mA
at current I/O
120 mA
85 mA
PROFIBUS DP add 53 mA (15 V supply) or 30 mA (24 V supply)
DeviceNet™ add 48 mA (24 V supply)
Analog output 0...5 (10) Vdc or 0 (4)...20 mA (sourcing output)
Digital communication standard: RS232;
options: PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, FLOW-BUS
Electrical connection
Analog/RS232 8 DIN (male)
PROFIBUS DP bus: 5-pin M12 (female);
power: 8 DIN (male)
Devicenet™ 5-pin M12 (male)
FLOW-BUS/Modbus-RTU/ASCII 5-pin M12 (male)

Technical specifications and dimensions subject to change without notice.

For dimensional drawings and hook-up diagrams please visit the productpage on our website

Downloads

Brochures
LIQUI-FLOW series L10-L20 brochure

Manuals
General manual digital instruments
Operating instructions digital instruments

Hook-up diagrams
Analog IO - RS232
DeviceNet
FLOW-BUS
Modbus-RTU
PROFIBUS DP