Bronkhorst

EX-FLOW F-106GX

Ex-Proof Mass Flow Meter for High Gas Flow

  • ATEX approval Cat.2, Zone 1
  • Also IECEx and TIIS certified
  • High accuracy, excellent repeatability
  • Virtually pressure and temperature independent
  • "Wafer type" for mounting between flanges (DN250 / 10")
Get a quote Request a demo Support
EX-FLOWF-106GX

Intrinsically Safe Gas Mass Flow Meters for high flow rates

Bronkhorst® EX-FLOW Mass Flow Meters (MFMs) are suited for precise gas flow measurement in ATEX Zone 1 hazardous areas. The MFM should be connected to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone). See Bronkhorst® E-8000 Series.

EX-FLOW model F-106GX covers flow ranges from 22...1100 m3n/h up to 220...11000 m3n/h (N2-equivalent) at operating pressures up to 40 bar.

The intrinsically safe measuring head of the flow meter is tested according to ATEX 114 Directive 2014/34/EU and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4 Gb.
Other certifications: IECEx (IECEx DEK14.0060) and TIIS (検・第TC21584号).


Technical specifications

Measurement system
Flow range, based on N2
(intermediate ranges available)
min. 22...1100 m3n/h
max. 220...11000 m3n/h

Accuracy (incl. linearity)
(based on actual calibration)

±1% FS up to 1100 m3n/h N2-equivalent; for higher flows please contact factory
Turndown 1:50 (2...100%)
Repeatability < 0,2% Rd

Time constant

5 seconds
Operating temperature -10…+70°C
Temperature sensitivity zero: < 0,05% FS/°C; span: < 0,05% Rd/°C
Leak integrity, outboard tested < 2 x 10-9 mbar l/s He
Attitude sensitivity max. error at 90° off horizontal 0,2% FS at 1 bar, typical N2
Warm-up time 30 min. for optimum accuracy
2 min for accuracy ± 2% FS
Mechanical parts
Material (wetted parts) stainless steel 316L or comparable
Pressure rating up to 40 bar abs (PN10, 16, 40);
for hazardous gases such as O2, H2, etc. do not exceed operating pressure of 10 bar; for higher pressure select a flanged type MFM, series F-107/F-117.
Process connections Wafer type, for mounting between flanges according to DIN DN250 or ANSI 10”
Seals standard: Viton®; options: EPDM, Kalrez® (FFKM)
Ingress protection (housing) IP65
Electrical properties
Signal circuit type of explosion protection: intrinsic safety Ex ib IIC, only for connection to a certified intrinsically safe circuit with the following maximum values:
  Ui = 28 V, Ii = 98 mA, Pi = 686 mW
  The effective internal capacitance between:
  Terminals 1 and 3: Ci = 1 nF;
  Effective internal inductance: Li = 0,3 mH
Output signal 15…20 mA (linear)

I/O signals via PS/Readout
(located in safe area)

analog: 0...5 Vdc, 0...10 Vdc, 0...20 mA, 4...20 mA;
digital: RS232, PROFIBUS DP, DeviceNet™, Modbus RTU or ASCII, PROFINET, EtherCAT®, FLOW-BUS
Electrical connection
Ex-proof measuring head Terminal connection, cable gland M16x1,5

Technical specifications and dimensions subject to change without notice.
For dimensional drawings and hook-up diagrams please visit the productpage on our website

Downloads

Brochures
EX-FLOW brochure

Manuals
Manual EX-FLOW meters and controllers - ATEX
Manual EX-FLOW meters and controllers - IECEx
Manual EX-FLOW meters and controllers - TIIS