Adam explains: IN-FLOW
EXPLANATION VIDEO
Do you want to learn more about the ins & outs of this series? Our colleague Adam will tell you all about it in this video.
Technical specifications
Type Of Media
Gases
Flow measuring principle
Thermal
Series range
For 0.014 mln/min - 11000 m3n/h
Accuracy
±0.5% Rd plus ±0.1% FS
Repeatability
<±0.2% Rd (or <±0.04% FS whichever is greater)
Max. Pressure bar(g)
700
Operating Temperature
-10…+70°C; 0...+50°C for ATEX zone 2, KCs, Class1 Div 2
Ingress Protection
IP65
IN-FLOW including Low-ΔP-FLOW models
These rugged IP65-styled flow instruments are well suited for industrial environments. The series includes 'high-flow' models suitable for gas flows up to 11.000 m3n/h and low pressure drop versions as well.
Search for a model
min. 0.2…10 mln/min
max. 0.4…20 mln/min
10 bar(g)
min. 0.42…21 mln/min
max. 0.042…2.1 ln/min
10 bar(g)
min. 0.028…1.4 ln/min
max. 0.24…12 ln/min
10 bar(g)
min. 0.28…14 ln/min
max. 0.5…25 ln/min
10 bar(g)
min. 0.17…8.5 ln/min
max. 1…50 ln/min
10 bar(g)
min. 0.8… 40 ln/min
max. 3…150 ln/min
10 bar(g)
min. 0.9…45 ln/min
max. 4…200 ln/min
10 bar(g)
min. 0,4…20 m3n/h
max. 4…200 m3n/h
40 bar(g)
min. 1…50 m3n/h
max. 10…500 m3n/h
40 bar(g)
min. 2…100 m3n/h
max. 20…1000 m3n/h
40 bar(g)
min. 3.6…180 m3n/h
max. 36…1800 m3n/h
40 bar(g)
min. 8…400 m3n/h
max. 80…4000 m3n/h
40 bar(g)
min. 14…700 m3n/h
max. 140…7000 m3n/h
40 bar(g)
min. 22…1100 m3n/h
max. 220…11000 m3n/h
40 bar(g)
min. 0.2…10 m3n/h
max. 20…1000 m3n/h
10 bar(g)
min. 0,4…20 m3n/h
max. 4…200 m3n/h
40 bar(g)
min. 1…50 m3n/h
max. 10…500 m3n/h
40 bar(g)
min. 2…100 m3n/h
max. 20…1000 m3n/h
40 bar(g)
min. 3.6…180 m3n/h
max. 36…1800 m3n/h
40 bar(g)
min. 0.2…10 m3n/h
max. 20…1000 m3n/h
10 bar(g)
min. 0.014…0.7 mln/min
max. 0.06…9 mln/min
100 bar(g)
min. 0,4…20 ln/min
max. 2…100 ln/min
100 bar(g)
min. 0,16…8 mln/min
max. 0,16…25 ln/min
100 bar(g)
min. 0,8…40 ln/min
max. 1,4…250 ln/min
100 bar(g)
min. 4…200 ln/min
max. 8…1600 ln/min
100 bar(g)
min. 0.3…15 m3n/h
max. 4…200 m3n/h
100 bar(g)
min. 1…50 m3n/h
max. 7.5…375 m3n/h
max. 10...500 m3n/h on request
100 bar(g)
min. 0.4…20 m3n/h
max. 4…200 m3n/h
100 bar(g)
min. 1…50 m3n/h
max. 10…500 m3n/h
100 bar(g)
min. 2…100 m3n/h
max. 20…1000 m3n/h
100 bar(g)
min. 3,6…180 m3n/h
max. 36…1800 m3n/h
100 bar(g)
min. 0,2…10 mln/min
max. 0,3…15 mln/min
200 bar(g)
min. 0,3…15 mln/min
max. 0,4…20 ln/min
200 bar(g)
min. 0,3…15 ln/min
max. 5…250 ln/min
200 bar(g)
min. 4…200 ln/min
max. 25…1250 ln/min
200 bar(g)
min. 0.3…15 m3n/h
max. 4…200 m3n/h
200 bar(g)
min. 1…50 m3n/h
max. 7.5…375 m3n/h
max. 10...500 m3n/h on request
200 bar(g)
min. 0,2…10 mln/min
max. 0,3…15 mln/min
400 bar(g)
min. 0,3…15 mln/min
max. 0,4…20 ln/min
400 bar(g)
min. 0,3…15 ln/min
max. 5…250 ln/min
400 bar(g)
min. 4…200 ln/min
max. 25…1250 ln/min
400 bar(g)
min. 0.3…15 m3n/h
max. 4…200 m3n/h
400 bar(g)
min. 1…50 m3n/h
max. 7.5…375 m3n/h
max. 10...500 m3n/h on request
400 bar(g)
min. 0.3…15 mln/min
max. 2…100 ln/min
700 bar(g)
min. 4…100 ln/min
max. 5…250 ln/min
700 bar(g)
min. 4…200 ln/min
max. 25…1250 ln/min
700 bar(g)
min. 0.014…0.7 mln/min
max. 0.06…9 mln/min
64 bar(g)
min. 0.2…10 mln/min
max. 0.4…20 mln/min
10 bar(g)
min. 0,4…20 ln/min
max. 2…100 ln/min
64 bar(g)
min. 0,16…8 mln/min
max. 0,5…25 ln/min
64 bar(g)
min. 0.42…21 mln/min
max. 0.042…2.1 ln/min
10 bar(g)
min. 0.028…1.4 ln/min
max. 0.24…12 ln/min
10 bar(g)
min. 0.8…40 ln/min
max. 5…250 ln/min
64 bar(g)
min. 0.28…14 ln/min
max. 0.5…25 ln/min
10 bar(g)
min. 0.17…8.5 ln/min
max. 1…50 ln/min
10 bar(g)
min. 4…200 ln/min
max. 33…1670 ln/min
64 bar(g)
min. 0.3…15 m3n/h
max. 4…200 m3n/h
64 bar(g)
min. 1…50 m3n/h
max. 7.5…375 m3n/h
max. 10...500 m3n/h on request
100 bar(g)
min. 0,014…0,7 mln/min
max. 0,18…9 mln/min
100 bar(g)
min. 0,4…20 ln/min
max. 2…100 ln/min
100 bar(g)
min. 0.16…8 mln/min
max. 0.5…25 ln/min
100 bar(g)
min. 0.8…40 ln/min
max. 5…250 ln/min
100 bar(g)
min. 4…200 ln/min
max. 33…1670 ln/min
100 bar(g)
min. 0.3…15 m3n/h
max. 4…200 m3n/h
100 bar(g)
min. 1…50 m3n/h
max. 7.5…375 m3n/h
max. 10...500 m3n/h on request
100 bar(g)
min. 0.3…15 mln/min
max. 0.4…20 ln/min
200 bar(g)
min. 0.2…10 mln/min
max. 10...500 mln/min
400 bar(g)
min. 10…500 mln/min
max. 0.2…10 ln/min
400 bar(g)
min. 0.2…10 ln/min
max. 2…100 ln/min
400 bar(g)
min. 0.2…10 mln/min
max. 10…500 mln/min
700 bar(g)
min. 10…500 mln/min
max. 0,2…10 ln/min
700 bar(g)
min. 2…10 ln/min
max. 2…100 ln/min
700 bar(g)
Downloads
Manuals
-
PDF
Manual operation instructions digital instruments (9.17.023)
-
PDF
Manual digital Mass Flow/Pressure instruments laboratory style & IN-FLOW (9.17.022)
-
PDF
Quick Start Guide IN-FLOW (9.17.193)
Hook-up diagrams
-
PDF
Hook Up Diagram Industrial style MBC3 RS232 Analog (9.16.126)
-
PDF
Hook Up Diagram Ind MBC3 CANopen (9.16.216)
-
PDF
Hook Up Diagram Industrial MBC3 Devicenet (9.16.129)
-
PDF
Hook Up Diagram M12 Industrial Ethernet (9.16.253)
-
PDF
Hook Up Diagram Industrial MBC3 FLOW-BUS (9.16.127)
-
PDF
Hook Up Diagram multibus instruments industrial style MBC3 Modbus (9.16.130)
-
PDF
Hook Up Diagram Industrial Style, Optional Bus And IO Configurations (9.16.125)
-
PDF
Hook Up Diagram multibus instruments industrial style MBC3 PROFIBUS DP (9.16.128)
-
PDF
Hook Up Diagram Multibus instruments lab-style MBC3 PROFINET (9.16.207)
Certificates
-
PDF
Certificate KCs IN-FLOW Mass Flow Meter
-
PDF
Certificate FM US FM17US0363X IN-FLOW
-
PDF
Certificate FM Canada FM17CA0173X IN-FLOW
-
PDF
KEMA 10ATEX0111X (Zone 2)
-
PDF
EU Declaration of Conformity IN-FLOW Ex Cat3
-
PDF
EU Declaration of Conformity instruments (9.06.021)
-
PDF
KCs Certificate IN-FLOW mass flow controller
Brochures
-
PDF
Brochure IN-FLOW
-
PDF
IN-FLOW overview flow ranges
Dimensional Drawing
-
PDF
Dimensional Drawing EL-FLOW / IN-FLOW MBC Cases (7.05.445)
Where is the IN-FLOW used?
Flow controllers for hydrogen storage
Learn how flow controllers are used in the research of alternative methods for hydrogen storage in metal hydride for fuel cells and vehicles.
Read more
Controllers for chemical reactor systems
How to control pressure and flow in chemical reactor? Check out the solution: an accurate pressure controller combined to a mass flow controller.
Read more
Accessories
Control valves
For a wide variety of gas, liquid or pressure control applications
19
IN-LINE gas filters
Compact in-line filters for gas flow applications
8
BRIGHT
Compact Local Readout and Control Module
4
Need help?
Whether you’re choosing a solution or need on-site support, we’re here to help. From expert advice to reliable service, you can count on us to be close by and ready to assist.